Performance of plasma sputtered Fuel Cell electrodes with ultra-low Pt loadings - Archive ouverte HAL
Article Dans Une Revue Electrochemistry Communications Année : 2009

Performance of plasma sputtered Fuel Cell electrodes with ultra-low Pt loadings

Résumé

Ultra-low Pt content PEMFC electrodes have been manufactured using magnetron cosputtering of carbon and platinum on a commercial E-Tek® uncatalyzed gas diffusion layer in plasma fuel cell deposition devices. Pt loadings of 0.16 and 0.01 mg cm-2 have been realized. The Pt catalyst is dispersed as small clusters with size less than 2 nm over a depth of 500 nm. PEMFC test with symmetric electrodes loaded with 10 μg cm-2 led to maximum reproducible power densities as high as 0.4 W cm-2 and 0.17 W cm-2 with Nafion®212 and Nafion®115 membranes, respectively.
Fichier principal
Vignette du fichier
ElectrochemComm_brault.pdf (244.82 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00361475 , version 1 (15-02-2009)

Identifiants

Citer

Marjorie Cavarroc, A. Ennadjaoui, Mathieu Mougenot, Pascal Brault, Raphael Escalier, et al.. Performance of plasma sputtered Fuel Cell electrodes with ultra-low Pt loadings. Electrochemistry Communications, 2009, 11 (4), pp.858-861. ⟨10.1016/j.elecom.2009.02.012⟩. ⟨hal-00361475⟩
199 Consultations
307 Téléchargements

Altmetric

Partager

More