Validity of the one-dimensional limp model for porous materials
Résumé
A straightforward criterion to determine the limp model validity for porous materials is addressed here. The limp model is an "equivalent fluid" model which gives a better description of the porous behavior than the well known "rigid frame" model. It is derived from the poroelastic Biot model assuming that the frame has no bulk stiffness. A criterion is proposed to identify the porous materials for which the limp model can be used. It relies on a new parameter, the Frame Stiffness Influence FSI based on porous material properties. The critical values of FSI under which the limp model can be used, are determined using a 1D analytical modeling for a specific boundary set: radiation of a vibrating plate covered by a porous layer.
Origine | Fichiers produits par l'(les) auteur(s) |
---|