Contrast evaluation of the polarimetric images of different targets in turbid medium: possible sources of systematic errors - Département de physique Accéder directement au contenu
Communication Dans Un Congrès Année : 2010

Contrast evaluation of the polarimetric images of different targets in turbid medium: possible sources of systematic errors

Résumé

Subsurface polarimetric (differential polarization, degree of polarization or Mueller matrix) imaging of various targets in turbid media shows image contrast enhancement compared with total intensity measurements. The image contrast depends on the target immersion depth and on both target and background medium optical properties, such as scattering coefficient, absorption coefficient and anisotropy. The differential polarization image contrast is usually not the same for circularly and linearly polarized light. With linearly and circularly polarized light we acquired the orthogonal state contrast (OSC) images of reflecting, scattering and absorbing targets. The targets were positioned at various depths within the container filled with polystyrene particle suspension in water. We also performed numerical Monte Carlo modelling of backscattering Mueller matrix images of the experimental set-up. Quite often the dimensions of container, its shape and optical properties of container walls are not reported for similar experiments and numerical simulations. However, we found, that depending on the photon transport mean free path in the scattering medium, the above mentioned parameters, as well as multiple target design could all be sources of significant systematic errors in the evaluation of polarimetric image contrast. Thus, proper design of experiment geometry is of prime importance in order to remove the sources of possible artefacts in the image contrast evaluation and to make a correct choice between linear and circular polarization of the light for better target detection.
Fichier non déposé

Dates et versions

hal-00752417 , version 1 (15-11-2012)

Identifiants

  • HAL Id : hal-00752417 , version 1

Citer

Tatiana Novikova, Arnaud Bénière, François Goudail, Antonello de Martino. Contrast evaluation of the polarimetric images of different targets in turbid medium: possible sources of systematic errors. Polarization: Measurement, Analysis, and Remote Sensing IX, Apr 2010, Orlando, Florida, United States. pp.76720Q. ⟨hal-00752417⟩
241 Consultations