Custom real-time ultrasonic instrumentation for simultaneous mixture and flow analysis of binary gases in the CERN ATLAS experiment - Centre de Physique des Particules de Marseille Accéder directement au contenu
Communication Dans Un Congrès Année : 2017

Custom real-time ultrasonic instrumentation for simultaneous mixture and flow analysis of binary gases in the CERN ATLAS experiment

M. Alhroob
  • Fonction : Auteur
M. Battistin
  • Fonction : Auteur
S. Berry
  • Fonction : Auteur
A. Bitadze
  • Fonction : Auteur
P. Bonneau
  • Fonction : Auteur
G. Boyd
  • Fonction : Auteur
O. Crespo-Lopez
  • Fonction : Auteur
C. Degeorge
  • Fonction : Auteur
C. Deterre
  • Fonction : Auteur
B. Di Girolamo
  • Fonction : Auteur
M. Doubek
  • Fonction : Auteur
G. Favre
  • Fonction : Auteur
A. Hasib
  • Fonction : Auteur
S. Katunin
  • Fonction : Auteur
D. Lombard
  • Fonction : Auteur
A. Madsen
  • Fonction : Auteur
S. Mcmahon
  • Fonction : Auteur
K. Nagai
  • Fonction : Auteur
A. O'Rourke
  • Fonction : Auteur
B. Pearson
  • Fonction : Auteur
D. Robinson
  • Fonction : Auteur
C. Rossi
  • Fonction : Auteur
E. Stanecka
  • Fonction : Auteur
M. Strauss
  • Fonction : Auteur
V. Vacek
  • Fonction : Auteur
R. Vaglio
  • Fonction : Auteur
J. Young
  • Fonction : Auteur
L. Zwalinski
  • Fonction : Auteur

Résumé

Custom ultrasonic instruments have been developed for simultaneous monitoring of binary gas mixture and flow in the ATLAS Inner Detector. Sound transit times are measured in opposite directions in flowing gas. Flow rate and sound velocity are respectively calculated from their difference and average. Gas composition is evaluated in real-time by comparison with a sound velocity/composition database, based on the direct dependence of sound velocity on component concentrations in a mixture at known temperature and pressure. Five devices are integrated into the ATLAS Detector Control System. Three instruments monitor coolant leaks into N 2 envelopes of the silicon microstrip and Pixel detectors. Resolutions better than ±2×10−5 and ±2×10−4 are seen for C 3 F 8 and CO 2 leak concentrations in N 2 respectively. A fourth instrument detects sub-percent levels of air ingress into the C 3 F 8 condenser of the new thermosiphon coolant recirculator. Following extensive studies a fifth instrument was built as an angled sound path flowmeter to measure the high returning C 3 F 8 vapour flux (∼1.2kgs−1) . A precision of <2.3% FS for flows up to 10ms−1 was demonstrated. These instruments have many potential applications where continuous binary gas composition measurement is required, including hydrocarbon and anaesthetic gas mixtures.

Dates et versions

hal-01584661 , version 1 (09-09-2017)

Identifiants

Citer

M. Alhroob, M. Battistin, S. Berry, A. Bitadze, P. Bonneau, et al.. Custom real-time ultrasonic instrumentation for simultaneous mixture and flow analysis of binary gases in the CERN ATLAS experiment. 14th Vienna Conference on Instrumentation, Feb 2016, Vienna, Austria. pp.273-277, ⟨10.1016/j.nima.2016.04.104⟩. ⟨hal-01584661⟩
81 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More